最新在線精品國自拍視頻_婷婷六月无毒综合激情_国产免费一级视频_日本丰满熟妇VIDEOSSEX_日本人与黑人videos系列_伊人久久大香线蕉无限次_正在播放酒店精品少妇约_很黄的爱爱高潮小说的软件_最新日韩欧美一区二区三区在线_色欲洲av无码精品国产午夜亚色

客服電話:
021-61998208

Mouse C4a(Complement Component 4a) ELISA Kit
  • Mouse C4a(Complement Component 4a) ELISA Kit

Mouse C4a(Complement Component 4a) ELISA Kit

小鼠補(bǔ)體試劑盒
Mouse C4a(Complement Component 4a) ELISA Kit本試劑盒運(yùn)用雙抗體夾心ELISA法定量測(cè)定人組織勻漿、細(xì)胞裂解液和其他生物液體C4a中含量。
價(jià)格 2280
貨號(hào): KL-0884Mo
適應(yīng)種屬: Mouse
檢測(cè)范圍: 78.125-5000pg/ml
靈敏度: 46.875pg/ml

Mouse C4a(Complement Component 4a) ELISA Kit


Chinese name?:小鼠補(bǔ)體試劑盒

Catalogue No.:KL-0884Mo

Nickname:C4a|C4A|C4AD|C4S|CO4|CPAMD2|RG|Complement Component 4a ELISA Kit?

test method:Sandwich ELISA, Double Antibody

Size48T/96T

Range: 78.125-5000pg/ml?

Sensitivity: 46.875pg/ml?

Reactivity:Mouse

Storage:2-8 ℃ for 6 months


Kit Components:

No.

Item

Specifications(48T/96T)

Storage

KL001

ELISA Microplate(Dismountable)

8×6/8×12

4°C/-20°C

KL002

Lyophilized Standard

vial/2 vial

4°C/-20°C

KL039

Sample/Standard Dilution Buffer

10ml/20ml

4°C

KL003

Biotin-labeled Antibody(Concentrated)

60ul/120ul

4°C(protect from light)

KL040

Antibody Dilution Buffer

5ml/10ml

4°C

KL034

HRP-Streptavidin Conjugate(SABC)

60ul/120ul

4°C(protect from light)

KL049

SABC Dilution Buffer

5ml/10ml

4°C

KL024

TMB Substrate

5ml/10ml

4°C(protect from light)

KL026

Stop Solution

5ml/10ml

4°C

KL038

Wash Buffer(25X)

15ml/30ml

4°C

KL006

Plate Sealer

3/5pieces


KL007

Product Description

1 copy


Specificity:

This assay has high sensitivity and excellent specificity for detection of C4a ?. No significant cross-reactivity or interference between C4a ?and analogues was observed.

Note: Limited by current skills and knowledge, it is difficult for us to complete the cross-reactivity detection between C4a ?and all the analogues, therefore, crossr eaction may still exist.

Recovery:

Matrices listed below were spiked with certain level of C4a and the recovery rates were calculated by comparing the measured value to the expected amount of ?C4a in samples.


Matrix

Recovery Range (%)

Average (%)

Serum(n=5)

94-105

100

EDTA Plasma(n=5)

89-97

93

Heparin Plasma(n=5)

92-105

100

Linearity:

The linearity of the kit was assayed by testing samples spiked with appropriate concentration C4a and their serial dilutions. The results were demonstrated by percentage of calculated concentration to the expectation.

Sample

1:2

1:4

1:8

Serum(n=5)

85-95%

86-105%

88-101%

EDTA Plasma(n=5)

82-101%

83-90%

94-100%

Heparin Plasma(n=5)

81-100%

82-99%

87-100%

Precision:?

Intra-Assay: CV<8%

Inter-Assay: CV<10%

Stability:

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% within the expiration date under appropriate storage condition.

Principle of the Assay:

Operation Procedure:

This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Capture ?antibody was pre-coated onto 96- well plates. And the biotin conjugated antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and washed with wash buffer. HRP-Streptavidin was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that ?changed into yellow after adding acidic stop solution. The density of yellow is proportional to the target amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of targetcan be calculated.

Precautions:

1.To inspect the validity of experiment operation and the appropriateness of sample dilution proportion, pilot experiment using standards and a small number of samples isrecommended.

2.After opening and before using, keep platedry.

3.Beforeusingthekit,spintubesandbringdownallcomponentstothebottomoftubes.

4.Storage TMB reagents avoidlight.

5.Washingprocessisveryimportant,notfullywasheasilycauseafalsepositiveandhighbackground.

6.Duplicate well assay is recommended for both standard and sampletesting.

7.Don’tletmicroplatedryattheassay,fordryplatewillinactivateactivecomponentsonplate.

8.Don’treusetipsandtubestoavoidcrosscontamination.

9.Avoid using the reagents from different batchestogether.

Material Required but Not Supplied:

1.Microplate reader(wavelength:450nm)。

2.37°Cincubator。

3.Automated platewasher。

4.Precision single and multi-channelpipette and disposable tips。

5.Clean tubes and Eppendorftubes。

6.Deionized or distilledwater。

Washing:

Manual: Discard the solution in the plate without touching the side walls. Clap the plate on absorbent filter papers or other absorbent material. Fill each well completely with 350ul wash buffer and soak for1to 2minutes,then aspirate contents from theplate,andclaptheplateonabsorbentfilterpapersorotherabsorbentmaterial.

Automatic: Aspirate all wells, and then wash plate with 350ul wash buffer. After the final wash, invert plate, and clap the plate on absorbent filter papers or other absorbent material. It is recommended that the washer shall be set for soaking1 minute.(Note:settheheightoftheneedles;besurethefluidcanbesippedupcompletely)。

在線客服
專業(yè)的客服團(tuán)隊(duì),歡迎在線資訊
客服時(shí)間: 周一至周五9:00 - 18:00